Product Detail
BA150 Hinged Door
Enhance airflow andfreshness within yourenvironment; our Hingeddoors facilitate wide openings, fostering optimalventilation to create arefreshing sanctuary year-round.

Quick Specs
BA150 Hinged Door Quick Specs
Fast product-selection information for early specification, enquiry and comparison.
Product Overview
Practical Aluminium Door System for Project-Based Supply
Water : 200PA Design wind pressure : 1170PA/3000PA 5+12Ar+5 / 6+12Ar+6 / 8+9Ar+8
- Water : 200PA
- Design wind pressure : 1170PA/3000PA
- 5+12Ar+5 / 6+12Ar+6 / 8+9Ar+8

Configurations
Product Configuration / Opening Diagrams
Configuration drawings illustrate the proposed opening arrangement, fixed and operable elements, and section details. Confirm dimensions, hardware, support conditions and installation interfaces in the approved project drawings.

System Data
System Parameters
Structural and system-level information is kept separate from glass, hardware and performance data so it is easier to review the product model.
| Series | MD150 |
|---|---|
| Product Category | MD150 Hinged Door |
| System Type | NON-Thermal break |
| Opening Method | |
| Frame / Sash Finish | Powder coated aluminium; standard and custom colours available |
| Project Customisation | Size, layout, glazing, hardware, colour and technical drawings should be confirmed from project drawings. |
Glass Data
Glass Specifications
Glass information is listed separately so build-ups and U-value references can be reviewed clearly.
| Available Glass Build-Up | 5mm+12Ar+5mm |
|---|---|
| Available Glass Build-Up | 6mm+12Ar+6mm |
| Available Glass Build-Up | 8mm+9Ar+8mm |
| Glazing | Visible Trans | Winter Nighttime U-Value | Summer Daytime U-Value |
|---|---|---|---|
| 5+12A+5 | 63% | Winter Nighttime -1.85W/m²k | Summer Daytime – 1.81W/m²k |
| 6+12A+6 | 72% | Winter Nighttime -1.85W/m²k | Summer Daytime – 1.83W/m²k |
| 8+9A+8 | 84% | Winter Nighttime -2.73W/m²k | Summer Daytime – 2.72W/m²k |
Glass-table U-value and solar heat gain figures describe the listed glazing, not a verified whole-window or whole-door rating. Confirm whole-assembly performance for the specified frame, glass and opening configuration.
Customisation
Glass Configuration Options
These options can be selected according to project requirements and final specification.
Hardware
Hardware Options
Hardware options can be selected according to project requirements, operation preference, locking needs and the final door specification.
Standard Hardware Reference
- KINLONG
Optional Hardware Upgrades
- Doric (Only for use without a flyscreen)
Colours
Standard Colour Options
Standard colour references are shown below. Custom powder coating can also be reviewed for project-specific requirements.
Performance
Maximum Performance
Performance data is separated from system structure and glass options for easier review.
| Water Tightness : | +200Pa |
|---|---|
| Ultimate Pressure | Positive Pressure Maximum pressure: +2.00 kPa |
| Ultimate Pressure | Negative Pressure Maximum pressure: -2.83 kPa |
| Air Tightness | Under pressure difference of: +/-75Pa |
| Air Tightness | Allowed air infiltration rate: 25.945m3/hr |
Note: Final product performance should be confirmed by project requirements, selected glass, configuration, site conditions and applicable Australian standards.
Applications
Where BA150 Hinged Door Is Used
Related Products
Related Products & Systems
Aluminium Doors
Return to the aluminium door systems collection page.
FAQ
BA150 Hinged Door FAQ
What should I check when selecting a hinged door?
For BA150 Hinged Door, confirm the opening direction, swing clearance, threshold, hardware and required clear passage on the door schedule. Single, double or pivot arrangements must be checked against the actual model drawing; a product-family name does not confirm every configuration is available.
Is BA150 Hinged Door thermally broken?
BA150 Hinged Door is listed as a non-thermally broken aluminium system. Double glazing does not convert a non-thermally broken frame into a thermally broken system. Compare verified whole-door U-value and SHGC data for the proposed assembly; generic glass figures are not a whole-system rating. See YourHome glazing guidance.
What double-glazing options are listed for BA150 Hinged Door?
The published glass build-ups are 5mm+12Ar+5mm; 6mm+12Ar+6mm; 8mm+9Ar+8mm. These are the listed options for this model, not interchangeable approvals for every opening size. Confirm glass type, safety requirements, coating and configuration with the project schedule. Published glass-only thermal values must not be represented as whole-door performance.
What locking and threshold details should I specify?
State the required locking arrangement, access requirements, threshold and adjoining floor levels for BA150 Hinged Door. Confirm compatible hardware and installation details in the approved schedule. Security, accessibility and weather performance are separate requirements and need evidence for the selected assembly.
Does an AS2047 report cover every configuration?
No. Documentation must identify the relevant series, opening type, dimensions, glass, hardware and permitted variations. Compare the covered structural, water and air performance with the project requirements. The compliance documents should be checked for applicability to BA150 Hinged Door; a report for another model is not interchangeable.
What information is needed for a quote?
For BA150 Hinged Door, send drawings and schedules showing project location, opening sizes, quantities, glazing and performance requirements, finishes and expected delivery timing. Identify installation and delivery responsibilities. The quote is developed from the agreed supply scope; no fixed price or delivery lead time is assumed.